View previous topic :: View next topic
|
| Author |
Message |
archi4er
Joined: 23 Sep 2004 Posts: 3
|
Posted: Fri Oct 08, 2004 12:46 pm Post subject: commercial building use wood stud, can they put one more |
    |
|
layer drywall to meet code? otherwise the contracter must replace all the wood stud with metal stud.
or any other solutions? |
|
| Back to top |
|
 |
LeCorbusier
Joined: 15 Apr 2004 Posts: 139
|
Posted: Fri Oct 08, 2004 1:13 pm Post subject: |
    |
|
there are 2 hr wood stud stud assemblies. And yes, you can usually add a layer of gwb to achieve this, but you should check with the local inspector or local codes. In NYC for example, you cannot use wood studs at all. Check the US National Gypsum Board Association for fire rated assemblies. http://www.gypsum.org/
http://www.gypsum.org/codeservices.html
Download ESR-1338 |
|
| Back to top |
|
 |
|